One product, practically every application. Magnum® Board is a technologically advanced building material that offers superior performance in every category when compared to traditional wood, gypsum and cement based products.

Magnum® Board is virtually impervious to fire, water, insects; does not feed mold or mildew; is non-toxic, non- flammable and non-combustible; is durable, maintains it’s dimensional stability – even when wet; and, has exceptional bonding characteristics.

Magnum® Board is a mineral based green builder product, and it is homogenous – no de-lamination.

Magnum® Board Products can have a positive impact on your Family’s health and safety while extending the life of your investment.

Magnum® Board is THE NEW GENERATION BUILDING MATERIAL.

 

Applications

Magnum™ Sheathing 
For use over metal or wood framed exteriors, Magnum® Sheathing is easily installed using either manual or pneumatic (strongly recommended) tools. Magnum® Sheathing can be finished with many products including paint, stucco, non-cementitous applications, tile and siding. And like all Magnum® Board products, Magnum® Sheathing is virtually impervious to fire, water, insects; does not feed mold or mildew; is non-toxic; provides dimensional stability even when wet; and an exceptional bonding surface. No more worrying about shrinkage if installed wet or damp.

Magnum™ Soffit

For use over metal or wood framed exteriors, Magnum® Soffit is easily installed using either manual or pneumatic (strongly recommended) tools. Magnum® Soffit, like all Magnum® Board products is virtually impervious to fire, water, insects; does not feed mold or mildew; is non-toxic; provides dimensional stability even when wet; and an exceptional bonding surface. Got rain at the job site? No problem with Magnum® Soffit. It can be installed wet or dry without the worry of shrinkage as it dries.

Magnum™ Fascia
For use over metal or wood framed exteriors Magnum® Fascia is easily installed using either manual or pneumatic (strongly recommended) tools. Magnum® Fascia, like all Magnum® Board products is virtually impervious to fire, water, insects; does not feed mold or mildew; is non-toxic; provides dimensional stability even when wet; and an exceptional bonding surface. Got rain at the job site? No problem with Magnum® Fascia. It can be installed wet or dry without the worry of shrinkage as it dries.

Magnum™ Wallboard & Ceiling Board

For use over metal or wood framing, Magnum® Wallboard and Magnum® Ceiling Board is easily installed using either manual or pneumatic (strongly recommended) tools. Magnum® Wallboard and Magnum® Ceiling Board, like all Magnum® Board products are virtually impervious to fire, water, insects; do not feed mold or mildew; are non-toxic; provides dimensional stability even when wet; and an exceptional bonding surface. Because of their smooth and durable surfaces, a level 5 drywall finish can be achieved with little effort. Magnum Board finishes can include painting, interior stucco, brick, tile, wall paper and other finish applications.

Magnum™ Backer and Underlayment

For use over metal or wood framed walls and floors; and as an underlayment for counter and vanity tops. Magnum® Backer and Underlayment are excellent for use in wet or damp areas such as bathrooms, laundry rooms, kitchens, basements and pool areas because they are virtually impervious to fire, water and insects; will not feed mold or mildew; and are non toxic. They provide excellent dimensional stability, bonding surface capability and durability. Finishes can include such products as latex paints, wall paper and tiles of all types. For tile applications use only thinset mortor adhesives. Avoid using Type 1 or Type 2 organic mastic adhesives which are significantly inferior to thinset

Magnum™ Shaft-liner & Area Separation Wall Sheathing
For use over metal or wood framing, Magnum® Shaft-liner, like all Magnum® Board Products, is virtually impervious to fire, water, insects; does not feed mold or mildew; is non-toxic, non-flammable and non-combustible. Magnum® Shaft-liner and Area Separation Wall panels are ideal for use in moisture prone vertical and horizontal shaft wall assemblies, stairwell and area separation wall applications. Based on fire testing, approximately one-half of Magnum® Panel thicknesses are required to achieve fire ratings – reducing both schedule and labor costs.

Magnum® Board Installation Guidelines

Storage and Handling

Even though Magnum® Board is virtually impervious to most elements, provides exceptional durability and dimensionally stabile – even when wet - for best results we recommend that you:

  • Keep material dry prior to and during installation
  • Store flat on dunnage
  • Do not stack other materials on top of Magnum® Board
  • Protect the material from jobsite dirt, and
  • Protect edges from damage

Cutting

Work Station
  1. Position cutting station so that wind will blow dust away from user or others in working area and allow for ample dust dissipation.
  2. Use one of the following methods based on the required cutting rate and jobsite conditions.

Cutting Methods

Best

  • Score and snap using carbide-tipped scoring knife or utility knife (Ability to use this method depends on thickness of Magnum® Board being installed.)
  • Fiber-cement shears (electric or pneumatic).

Better

  • Dust reducing circular saw equipped with appropriate blade and HEPA vacuum extraction.

Good (for low to moderate cutting only)

  • Dust reducing circular saw with appropriate saw blade.

NOTES:
Always use correct tools when executing cutting operations.
Even though Magnum® Board is a non-toxic building material, ALWAYS wear a dusk mask, safety glasses and follow MSDS Guidelines.

Fastening

Fastening with Pins

Product
Thickness
Fastener
Number
Tool
Estimated
Pressure
6MM (1/4”) ETF AKN-100-1050NA ETF Model 90 – 100PSI
8MM (5/16”) Pins – 1.5” Long 500 110 – 120 PSI
10MM (3/8”) thru Pins – 1.5” Long 500 110 – 120 PSI
19MM (3/4”) Pins – 1.5” Long 500 110 – 120 PSI

Fastening With “T” Nails

Product
Thickness
Fastener
Number
Tool
Estimated
Pressure
6MM (1/4”) ETF AKN-100-1025G ETF Model 100 – 120PSI
8MM (5/16”) T Nails – 1.25” Long 210 110 – 130 PSI
10MM (3/8”) thru T Nails – 1.25” Long 210 110 – 130 PSI
19MM (3/4”) T Nails – 1.25” Long 210 110 – 130 PSI

Fastening with “Hilti” Screws

Product
Thickness
Fastener
Number
Tool
6MM (1/4”) SG #8 Various Manual & Electric Drivers
8MM (5/16”) Hilti – 1.25”
10MM (3/8”) thru Hilti – 1.25”
19MM (3/4”) Hilti – 1.25”

NOTES:
1.Always follow Local, State and National Building Codes for fastening requirements.
2.If using metal, actual pressure required will depend on the gauge of metal and the diameter of pressure hose used.
3.Screw size will vary depending on actual thickness of materials and type of materials used.

Clean-up

During clean-up, dust and debris, NEVER dry sweep as it may excite dust particles into the user’s breathing area. Instead, wet debris down with a fine mist to suppress dust during sweeping, or use a HEPA vacuum to collect particles.

NOTES:
1.For maximum protection (lowest respirable dust production), Magnum® Building Products recommends always using “Best” level cutting methods where feasible.
2.Never use a power saw indoors.
3.Never use a circular saw blade that is inappropriate for the specific operation being undertaken.
4.Never dry sweep - use wet suppression methods or HEPA vacuum.
5.Never use a grinder or continuous rim diamond blade for cutting.

Safety

  1. For maximum protection (lowest respirable dust production), Magnum® Building Products recommends always using “Best” level cutting methods where feasible.
  2. We do not recommend use of a power saw indoors.
  3. Never use a circular saw blade that is inappropriate for the specific operation being executed.
  4. Never dry sweep. Use wet suppression methods or HEPA vacuum.
  5. Never use a grinder or continuous rim diamond blade for cutting.
  6. Even though Magnum® Board is a non-toxic building material, ALWAYS wear a dusk mask, safety glasses and follow MSDS Guidelines when working with Magnum® Board.
  7. ALWAYS follow local, state and national building codes where applicable.


Technical specifications

Spec Sheet is in development.

Call for details.

 

Testing

MAGNUM BOARD® by Magnum Building Products

Composed of MgO and MgCl fillers and fiber reinforcement.

A homogenous product that provides strength, flexibility and no delamination.

Tested to ASTM C1186, ASTM C1325 and ASTM C1396 as required by the International Code Council (ICC)

MAGNUM BOARD® is Virtually Impervious to:
   Fire – Non-Flammable (E84) and Non-Combustible (E136)
   Water – Does Not Feed Mold or Mildew
   Insects – Such as Termites.

MAGNUM BOARD® is Non-Toxic (U-Pitt Protocol)

MAGNUM BOARD® is approved for interior applications such as:
    Underlayment – Walls - Ceilings - Trim

MAGNUM BOARD® is approved for exterior applications such as:
    Wall substrate - EIFS – SIPS - Fascia – Soffit – Trim

Available in 4’ x 8’, 9’, 10’ and 12’ dimensions and 1/8” to 1” thicknesses. Available with tapered edges for jointing.

MAGNUM BOARD® is a registered trademark

 

MSDS

Link to MSDS pdf
 

Magnum Board Warranty

30 YEAR PRODUCT WARRANTY
Limited – Prorated – Transferable

1. Coverage
Magnum Building Products warrants to the first owner of the structure to which all Magnum® Sheathing products (hereinafter Product) is applied and the first transferee of such structure that, for a period of 30 years from the date of purchase, the Product will be free from manufacturing defects, including rotting, swelling, delamination and damage from termites, when properly installed and maintained according to Magnum Building Products published installation instructions. Should any such defect appear, Magnum Building Products will pay to repair or will provide replacement material, at its option, for the defective Product Magnum Building Products also reserves the right to refund the amount paid for the Product, subject to the prorating schedule set forth herein.
Under no circumstances and in no event shall Magnum Building Products be liable for any labor charges or other expenses whatsoever in connection with the removal or installation of either the original or replacement Product. In the event of repair or replacement under the terms of this warranty, the original warranty shall apply to the replaced or repaired product and will extend for the balance of the warranty period in effect at the time the Product proved defective.
The coverage offered by this warranty is intended to cover individual homeowners only.
If during the Warranty period, any Product proves to be defective, Magnum Building Products, in its sole discretion, will replace the defective Product before it is installed, or, during the first year, reimburse the covered person for resulting losses up to twice the retail cost of the defective portion of the Product. During the 2nd through the 30th year, the Warranty payment will be reduced by 3.3% each year such that after the 30th year no warranty will be applicable.

Number of Years of Use Obtained After Installation Magnum Building Products’ Prorated Share of Warranty Obligation
Year 1 Capped at twice the retail cost of the defective portion of the Product. Years 2 through 30 shall incur a 3.3% reduction per year.
If the original retail cost cannot be established by the covered person, the cost will be determined by Magnum Building Products in its sole and reasonable discretion. Magnum Building Products replacement of the defective Product or granting of a refund pursuant to Section 1 of this Warranty SHALL BE THE SOLE EXCLUSIVE REMEDY available to the covered persons with respect to any defect. Magnum Building Products will not refund or pay any costs in connection with labor or accessory materials. Any refund or material replacement by Magnum Building Products shall constitute a full settlement and release of all claims of any covered person hereunder for damages or other relief, and shall be a complete bar to any litigation filed subsequently to the covered person’s acceptance of such agreement.

2. Conditions of Warranty
The Product must be stored according to the manufacturer’s instructions at all times between purchase and installation.
The Product must be installed according to Magnum Building Products printed installation instructions and all building codes adopted by federal, state or local governments or government agencies and applicable to the installation.
Failure to install and finish the Product per the manufacturer’s published instructions may affect Product performance and voids the Warranty.

3. What the Customer Must Do
The claimant must provide proof that he/she is a covered person and notify Magnum Building Products in writing within 30 days after discovery of any claimed defect or failure covered by this Warranty and before beginning any permanent repair.
The claimant must provide proof of the date of purchase and installation, as well as proof of property ownership. All notifications should be sent to: Magnum Building Products, 46615 Tennis Island Road, Wellesley Island, NY 13640.
Upon discovery of a possible defect or failure, the covered person must immediately, and at the covered person’s own expense, provide protection of all property that could be affected until the defect or failure is remedied.
The property owner will be required to submit a sample and photographs of the defective material to Magnum Building Products for the analysis. Magnum Building Products will then investigate the claim and examine the material claimed to be defective.
If requested, the property owner must provide access for examination by an agent of Magnum Building Products. If a defect covered by this warranty is confirmed, Magnum Building Products, within a reasonable amount of time after the inspection, will repair or replace the Product, or refund the original purchase price of the defective Product, pursuant to the terms of this warranty.

4. Limitations
This warranty does not provide protection against any failure, defect or damage caused by situations and events beyond normal exposure conditions, including but not limited to:
+ Misuse, abuse, neglect or improper handling, shipping, storage or installation of the Product.
+ Improper application or application not in strict adherence to Magnum Building Products written application instructions.
+ Improper installation of stubs or other accessories.
+ Settlement or structural movement and /or movement of materials to which the Product is attached.
+ Damage from incorrect design of the structure.
+ Exceeding the maximum designed wind loads.
+ Use of accessories that do not properly receive and/or secure the Product.
+ Impact of foreign objects, fire, earthquake, flood, lightning, hurricane, tornado, severe weather (including, but not limited to, unusual climate conditions) or other casualty or act of God.
+ Growth of mold, mildew, fungi, bacteria, or any organism on any surface of the Product (whether on the exposed or unexposed surfaces) and in this respect, any claims of damage caused by mold or mildew are expressly excluded.
+ Lack of proper maintenance or any cause other than manufacturing defects attributable to Magnum Building Products. Magnum Building Products will have no responsibility hereunder for defective Product subjected to further processing or alteration after shipment.
+ Magnum Building Products reserves the right to discontinue or modify any of its Products without notice to the property owner/consumer and shall not be liable as a result of such discontinuance or modification. If Magnum Building Products replaces any material under this warranty, it may substitute Product designated by Magnum Building Products to be of comparable quality or price range in the event the Product initially installed has been discontinued or modified.

5. Other Conditions:
IN NO EVENT WILL MAGNUM BUILDING PRODUCTS BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABIITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT.

SOME STATES DO NOT ALLOW LIMITATIONS ON, OR THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY.

THIS WARRANTY REPLACES ALL OTHER ORAL OR WRITTEN WARRANTIES, LIABILITIES OR OBLIGATIONS OF MAGNUM BUILDING PRODUCTS. PERTINENT STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME FOLLOWING THE SALE A PROPERTY OWNER/CONSUMER MAY SEEK A REMEDY UNDER THE IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.

IN NO EVENT SHALL MAGNUM BUILDING PRODUCTS BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS, OR ANY PERSONS THEREIN, RESULTING FROM THE BREACH OF THE WARRANTY. NO FIELD REPRESENTATIVE OR DISTRIBUTOR OR DEALER OF MAGNUM BUILDING PRODUCTS IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY.

SOME STATES DO NOT ALLOW LIMITATIONS ON, OR THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY.